Grinding process common failure analysis--shrink coating and gel

8. Varnish thickening and gel

(1) Failure phenomenon The storage time of the polishing oil is too long, and it has exceeded the shelf life, and gradually cross-linked thickening and gelation have occurred;

Poor or poor sealing, especially high temperature; light transmission during the storage of the varnish; excess of UV and varnish initiators and adhesion promoters; excessive loading of inorganic silicon and crosslinkers; The resin in the system is not properly combined.

(2) Solution Replace the varnish within the shelf life; seal the top cover or use it with the cover, or store the varnish with a small humidity and dry (temperature 25 ~ C soil 3 ~ C) ventilation warehouse, Intrusion of water-repellent molecules leads to thickening or thickening of varnish; storage of opaque warehouses for storage of varnish; and UV varnish to control the amount of photoinitiator, caution in the use of cross-linking adhesion promoters; incomplete Gel, you can filter after adding some of the diluent; add Tianyang Chemical Factory 1-3% TM-3 coupling agent, while the water-based varnish can be added natural anti-friction agent 5% -20%.

Earth Switch

Earth Switch, Jn15-24/31.5 Indoor High Voltage Earthing Switch, China Earth Switch

Sunway Hanguang Electric Manufacturing Limited , http://www.sunway-interrupter.com