Wanjiale Disinfection Cabinet is a premium product developed by Guangdong Wanjiale Gas Appliance Co., Ltd. As a low-carbon, high-tech enterprise, Wanjiale focuses on the efficient use of clean energy and renewable resources, with an emphasis on technology, energy efficiency, environmental protection, and modern design. The company's strategic focus lies in gas appliances, aiming to enhance kitchen, bathroom, and living room experiences by offering high-quality, innovative products that bring convenience and comfort to daily life.
**1. How to Use:**
- **Power Button:** This button toggles the device between power-on and power-off states. Upon initial startup, it defaults to off. Press once to enter standby mode, and again to turn it off. In any active state, pressing this button will shut down the unit.
- **Adjustment + / - Buttons:** These buttons are used to increase or decrease working parameters. When selecting a function, they adjust the time or temperature settings. For clock or appointment settings, a single press decreases the value by 1, while holding the button for a few seconds increases or decreases the value by 5 per second.
- **Function Button:** This key cycles through different operating modes: Automatic → Upper Chamber Sterilization → Lower Chamber High-Temperature → Upper Chamber Ozone → Upper Chamber Drying. Once a mode is selected, the corresponding indicators light up, and the system allows adjustment of relevant parameters using the + and - buttons.
- **Appointment / Security Lock Button:** This button enables users to set a timer for automatic operation or lock/unlock the cabinet door.
**2. Machine Status Description:**
- **Power Off / On State:** The device can be in power-off, standby, working, or scheduled working states. When powered off, all functions stop, and only the Power button is operational. The display is off, but the clock continues to run in the background.
- **Standby Mode:** In this mode, the system is ready for use. All keys are functional, and the system clock is displayed. The electronic lock indicator lights up when activated. After a 10-second delay, the last selected mode is reactivated.
- **Working Mode:** During operation, the corresponding mode indicators light up, and the door locks automatically. The "Door Lock" indicator flashes during operation. After completion, the machine returns to standby. Different modes include:
- **Upper Chamber Sterilization:** Combines ozone disinfection and hot air drying. The ratio of disinfection to drying is approximately 2:1. The "Upper Chamber Ozone," "Lower Chamber Drying," and "Time Min" indicators are active, and the countdown is displayed.
- **Lower Chamber High Temperature:** Heats the lower chamber to a set temperature for 20 minutes before returning to standby. The "Lower Chamber High Temperature" and "Temperature ℃" indicators are lit.
- **Automatic Mode:** Simultaneously performs upper chamber sterilization and lower chamber heating. The "Auto," "Time Min," and "Temperature ℃" indicators alternate every 15 seconds.
- **Upper Chamber Ozone:** Applies ozone disinfection for a set duration. The "Upper Chamber Ozone" and "Time Min" indicators are active.
- **Upper Chamber Drying:** Uses hot air to dry items in the upper chamber. The "Upper Chamber Drying" and "Time Min" indicators are illuminated.
**3. Usage Precautions:**
- Always wash and rinse dishes before placing them in the disinfection cabinet to reduce energy consumption and improve efficiency.
- Avoid placing plastic or heat-sensitive items in the lower chamber. Instead, use the upper chamber for ozone sterilization to prevent damage.
- Do not place colored porcelain or glazed ceramics in the high-temperature compartment, as they may release harmful substances like lead or cadmium when exposed to heat.
- Arrange tableware vertically on the shelves for better ventilation and faster disinfection.
- Check the ozone generator during operation. If there is no blue light or unusual noise, it may indicate a malfunction and should be repaired immediately.
- Avoid opening the cabinet during operation to maintain effectiveness.
- After disinfection, wait 10 minutes before opening the cabinet for optimal results. A slight ozone smell is normal and harmless.
**4. Maintenance Tips:**
- Always unplug the device before cleaning.
- Clean the interior and exterior with a soft cloth or sponge and mild detergent. Avoid using harsh chemicals or solvents that could damage the surface.
- Never spray water directly into the cabinet, as it may cause electrical issues.
*Still paying out of your own pocket for home improvements? The Qi family offers installment plans with an ultra-low annual interest rate of 3.55% and a maximum loan amount of 1 million. Apply now and enjoy exclusive discounts.*
If you're interested in brand collaborations, content partnerships, or advertising opportunities, please contact us at [email@example.com].
#DisinfectionCabinet #KitchenAppliances #OzoneSterilizer #GasAppliances #HomeImprovement #SmartKitchen #EcoFriendly #ModernLiving #ApplianceTips #HomeAutomation
Backpack,Decorated with Shiny Letters,Fashion and Cute Kids Bag,Suitable For Computer Or Book
TAIZHOU ORCHIDLAND IMPORT&EXPORT CO.,LTD , https://www.orchidlandgifts.com